PT790Ex (Intrinsically Safe Professional Digital Radio)

TETRA Intrinsically Safe Professional Digital Radio
PT790Ex is the first TETRA digital radio in the industry that complies with both ia and IIC Ex. Standards, which meets the highest protection standard of energy industry. With its versatile early warning functions, the radio provides an all-round communication reliability in high-risk environments, thereby achieving high efficiency both in production and operation.

asking for a demo

Features

  • ia Ex. standard
  • Hydrogen-group IIC Ex. level
  • Emergency alarm and early warning
  • Robust noise-canceling technology for audio

Features

  • Durable and reliable – Compliant with MIL – STD – 810 C/D/E/F/G and IP67 standards – The screen is made of crack-control material
  • Versatile voice and data services
  • Support GPS, man-down, encryption, and authentication

Specifications

General

Frequency Range
320-380MHz
380-430MHz
405-475MHz
806-870MHz
Dimensions(H×W×D) mm 144.8 × 55 × 40.7
Weight 515g?with battery and antenna?
Battery 1800mAh Li-lon battery
Battery Life (TMO 5/5/90 duty cycle) >19hours
Operating Voltage 7.4V

User Interface

Display 1.8inch?160*128pixels?65536colors
Talk Group-TMO 6000
Talk Group-DMO 4000
Telephone book 2000
Inbox 400
Outbox 50
Drafts 50
Folder-TMO 200
Folder-DMO 50
State Message 200

RF Specifications

Channel Bandwidth 25KHz
RF Power Output 1W
RF Power Level Accuracy ±2dB
RF Power Control 5dB per step, 4 levels and 3 steps in total
Receiver Class ETSI EN 392-2/396-2 Class A and Class B
RX Sensitivity(Static)
?-116dBm?typical-117dBm?
806-870MHz: ?-115dBm?typical-116dBm?
RX Sensitivity(Dynamic)
?-106dBm?typical-108dBm?
806-870MHz: ?-105dBm?typical-106dBm?
Audio Power Output 1.2W
View all
Close

Environmental

Operating Temperature
-30°C ~ +60°C (non-hazardous environment)
-20°C ~ +50ºC (hazardous environment)
*50ºC: The operating temperature may vary. In an explosive gas atmosphere, it can reach up to 55ºC. For details, see Product Marking.
Storage Temperature -40? ~ +85?
Humidity
ETS 300-019-1-7 Class 7.3E
MIL-STD-810 G
Dust & Water Protection IP67 Per IEC60529; IP5X Per IEC60079-0:2011
Vibration,Drop&Shock
ETS 300-019-1-7 Class 5M3
MIL-STD 810 G
GJB150A-2009

GPS Specifications(For the Model with GPS)

RX Sensitivity
Acquisition sensitivity: -148dBm
Tracking sensitivity: -167dBm
Horizontal Position Accuracy ?2m (50% probable)@-130dBm
Cold Start (Time to First Fix) 26s
Hot Start (Time to First Fix) 1.5s
Note Conditions: Open Sky environment, 130dBm signal strength, 24H static